Thursday, September 13, 2012
Day Lighting
The tubular skylights will bring tons of natural light inside the SRM. Day light creates a nice indoor environment and better work conditions compared to artificial lighting!
The tubular skylights doing their job during overcast sky conditions and the diffusers have not been installed yet! We anticipate that no artificial lighting should be required during regular working hours.
How about all that natural light! We can't wait to see the impact of the light shelves on the south windows.
Attic Insulation
One of the positives about spray foam is that the insulation itself is air
resistant. The gas or air which does the majority of actual insulating is
trapped in bubbles inside the plastic foam matrix and can’t be washed out by air
flow. As the influence of air leakage on a building's energy
consumption is recognized, the SRM building is designed to try to get the building as
“air-tight” as possible. Installing spray foams where air is leaking through the
building envelope can reduce that flow rate.
The design of the SRM building turned to a hybrid insulation systems often referred to as flash and batt insulation. To fill the empty roof assembly cavity, a flash coat of closed cell foam was applied to the interior side of the roof to a thickness of 3 inches, and then a low density batt was installed to fill in the space before the edge of the truss members. The result is the best of both worlds – high R-value of the fiberglass batt combined with the air tightening effects of spray foam!
The flash coat of foam is installed first.
Batt insulation is applied over the foam.
The design of the SRM building turned to a hybrid insulation systems often referred to as flash and batt insulation. To fill the empty roof assembly cavity, a flash coat of closed cell foam was applied to the interior side of the roof to a thickness of 3 inches, and then a low density batt was installed to fill in the space before the edge of the truss members. The result is the best of both worlds – high R-value of the fiberglass batt combined with the air tightening effects of spray foam!
The flash coat of foam is installed first.
Batt insulation is applied over the foam.
Insulation
One of the key features of the building is it's exterior wall framing and super-insulation.
Using an exterior double wall, the design provides a complete perimeter thermal brake by leaving an air gap between the interior and exterior studs. This air gap will later be filled with insulation.
If you pay close attention to this picture, you will see that there are two sets of studs, headers and runners! It might seem like overkill but the whole idea is to have an air-tight super insulated building envelope.
Can you imagine walls full of newspaper? For this project we are using blown in wet cellulose insulation. It's made of recycled newspaper! How cool is that? Basically paper pulp! This makes blown in wet cellulose insulation a wonderful Green product.
The cellulose is blown in wet in the cavities of the walls under pressure to make the product stick to the walls and fill in the studs of the frame. When the insulation dries it stays in place and is very dense. Blown in wet cellulose insulation is up to 25% more dense than fiberglass insulation. It also fills in voids that fiberglass is not very good at doing such as around light switches and corners. It also contrubues to keeping the wall air-tight. This saves energy on heating and cooling over the typical fiberglass insulation.
This image shows how the air space between the exterior sheathing of the wall and the space between the two studs, is filled with high density wet cellulose.

Once the first layer of wet insulation is installed and is dry, a mesh is placed on the wall and a second layer of hard pack loose celluluse fills in the remainding wall cavity.
There is also little to no waste. Whatever falls on the floor, the installer can place back into the blower!!!
With this wall assembly, the building will be able to achieve an R-value of 49 on its exterior walls! The super-insulated windows combined with the doors and roof insulation will keep the interior nicely insulated and with low energy usage for cooling and heating. The USGBC has anticipated that the project will obtain 19 points on its energy consuption credit. That is simply awesome!
Using an exterior double wall, the design provides a complete perimeter thermal brake by leaving an air gap between the interior and exterior studs. This air gap will later be filled with insulation.
If you pay close attention to this picture, you will see that there are two sets of studs, headers and runners! It might seem like overkill but the whole idea is to have an air-tight super insulated building envelope.
Can you imagine walls full of newspaper? For this project we are using blown in wet cellulose insulation. It's made of recycled newspaper! How cool is that? Basically paper pulp! This makes blown in wet cellulose insulation a wonderful Green product.
The cellulose is blown in wet in the cavities of the walls under pressure to make the product stick to the walls and fill in the studs of the frame. When the insulation dries it stays in place and is very dense. Blown in wet cellulose insulation is up to 25% more dense than fiberglass insulation. It also fills in voids that fiberglass is not very good at doing such as around light switches and corners. It also contrubues to keeping the wall air-tight. This saves energy on heating and cooling over the typical fiberglass insulation.
This image shows how the air space between the exterior sheathing of the wall and the space between the two studs, is filled with high density wet cellulose.

Once the first layer of wet insulation is installed and is dry, a mesh is placed on the wall and a second layer of hard pack loose celluluse fills in the remainding wall cavity.
There is also little to no waste. Whatever falls on the floor, the installer can place back into the blower!!!
With this wall assembly, the building will be able to achieve an R-value of 49 on its exterior walls! The super-insulated windows combined with the doors and roof insulation will keep the interior nicely insulated and with low energy usage for cooling and heating. The USGBC has anticipated that the project will obtain 19 points on its energy consuption credit. That is simply awesome!
August Update
It's been while since we last updated the blog. So here's a quick update!
DCM visited the site during the last week of August to witness the progress of the work first hand. We were really impressed with the contractor's disciplined crew and the cleanliness and order of the site. Kudos to our friends at Loven Construction and CDE!
The SRM building is definitely shaping up.
DCM visited the site during the last week of August to witness the progress of the work first hand. We were really impressed with the contractor's disciplined crew and the cleanliness and order of the site. Kudos to our friends at Loven Construction and CDE!
The SRM building is definitely shaping up.